If, for some reason (e. g. excessively high relative speed), it was not
possible to read all the digits, on the output of the data Fhex is output as
an error message from the point at which the data were no longer read
from the data carrier.
from the data carrier to the memory in the read station and stored there
優(yōu)勢安士能標識系統(tǒng),EUCHNER標識系統(tǒng) 企業(yè)QQ:2880626087 ; 手機;() 郵箱;@163.com ;周彩云 地址:上海市嘉定區(qū)江橋嘉涌路99弄6號713室
The ident system CIS is mostly used in installation as a read-only system
with the 4-bit parallel interface. The advantage of the parallel interface is
simple integration into the control system and the transparent representation
and outputs (I/O), represent at a point in time a related hex digit using
high/low levels (24 V/0 V). After the read station is switched on, the level
on all 4 wires is initially high. If a data carrier now enters the operating
distance of the read station, fi rst the data are automatically transferred
and on again. In the case of the CIS3A-Mini it is also possible to delete
the temporary memory in the read station via a reset pulse. If there is
a data carrier in front of the read head, the data are transferred again
automatically. temporarily. In the second step, the data are actively retrieved from the
memory in the read station by the control system. For the second step
it is no longer necessary for the data carrier to be in the read head's
operating distance.
The read station saves the data from a data carrier read until the next
data carrier is fed to the read station or the read station is switched off
available in the memory on the read station. If in the case of the CIS3/CIS3A
In the fi rst step, it is signaled to the control system via the high level on
the STROBE output on the read station that there is a data carrier in the
operating distance and new data are available in the memory on the read
of the data. Quick and therefore low-cost integration into any type
of PLC is possible.
The 4 data wires, which are connected directly to the PLC via inputs
station. The STROBE output is set to the high level when the fi rst 4 hex
digits on the CIS3/CIS3A and the fi rst 8 hex digits on the CIS3A Mini are
more than 4 hex digits are required in the application, it is necessary to
wait long enough until all the digits have been transferred to the memory